﻿<?xml version="1.0" encoding="utf-8"?>
<ManageTool>
  <ToolTips>
    <!-- GTEPS -->
		<ToolTip Command="GTEPS" ControlID="Mode" Caption="Mode" Text="Working mode of the external power supply monitoring."/>
		<ToolTip Command="GTEPS" ControlID="MinThreshold" Caption="Min Threshold" Text="The lower limit of the voltage of the external power supply to trigger the alarm."/>
		<ToolTip Command="GTEPS" ControlID="MaxThreshold" Caption="Max Threshold" Text="The upper limit of the voltage of the external power supply to trigger the alarm."/>
    <ToolTip Command="GTEPS" ControlID="SamplePeriod" Caption="Sample Period" Text="The sampling period to measure the external power supply."/>
    <ToolTip Command="GTEPS" ControlID="DebounceTime" Caption="Debounce Time" Text="The time for debouncing to avoid abnormal voltage drop of the external power supply."/>
    <!--<ToolTip Command="GTEPS" ControlID="OutputID" Caption="Output ID" Text="Specify the ID of the output port to generate specified waveform after the trigger condition meets."/>
    <ToolTip Command="GTEPS" ControlID="OutputStatus" Caption="Output Status" Text="Set the final status of the output port when the waveform remains high or low."/>
    <ToolTip Command="GTEPS" ControlID="Duration" Caption="Duration" Text="Set half-cycle time of square-wave."/>
    <ToolTip Command="GTEPS" ControlID="ToggleTimes" Caption="Toggle Times" Text="The number of square-wave generated from output port."/>-->
    <ToolTip Command="GTEPS" ControlID="SyncWithFRI" Caption="Sync With FRI" Text="Besides the +RESP:GTEPS alarm report, the device can also send the voltage of external power supply periodically along with the fixed message."/>
    <ToolTip Command="GTEPS" ControlID="VoltageMarginError" Caption="Voltage Margin Error" Text="This parameter will be used together with &lt;Min Threshold&gt; and &lt;Max Threshold&gt;, which indicates the voltage margin error of the &lt;Min Threshold&gt; and &lt;Max Threshold&gt; parameters."/>
    <ToolTip Command="GTEPS" ControlID="DebounceVoltageThreshold" Caption="Debounce Voltage Threshold" Text="This parameter will be used together with &lt;Debounce Time&gt;."/>
    <ToolTip Command="GTEPS" ControlID="MPNValidityTime" Caption="MPN/MPF Validity Time" Text="The validity time for detecting the device connecting or disconnecting main power supply."/>
  </ToolTips>
</ManageTool>